Multi-line 2 AGC Application Software series 4.x.

You’re about to download Multi-line 2 AGC Application Software series 4.x.

You have chosen to download our software.

Within a few seconds, you will receive an email containing a download link.

Having trouble using the software? Please contact support@deif.com. 

Best regards, 

DEIF A/S

The software is subject to copyright DEIF A/S
By following the above mentioned link and downloading the file you automatically accept DEIF A/S copyright and license agreement (EULA). The license agreement can be found on www.deif.com/software

This software applies to the following DEIF products:

You’re about to download 4.83.4

The main changes implemented since the last version are as follows:

PM compatibility: 1.24.2

 

Corrections:
• Change of ID to Run with Run one MAINS during active LTO is now working correctly.

Ver. Date Description

4.83.4

01.03.2024

PM compatibility: 1.24.2

 

Corrections:
• Change of ID to Run with Run one MAINS during active LTO is now working correctly.

4.83.3

27.09.2023

PM compatibility: 1.24.2

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

Corrections:

• RMB T4: When back synchronising to the mains, the display automatically shows the synchroscope. The buzzer in the RMB box also sounds when the static synchronisation check is fulfilled.

4.83.2

14.09.2023

PM compatibility: 1.24.2

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

Corrections:

• Manual PMS priority update via digital input or M-Logic secured to only take place on one DG within 10 seconds.
• Manual PMS priority update via digital input or M-Logic now works in 32DG applications.
• When writing a batch file, the correct language is not applied instantly in the USW when using Ethernet. This has been improved with a status text to show the user what happens.

4.83.1

13.06.2023

PM compatibility: 1.24.2

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

Corrections:

  • CAN transmit on the EIC line can no longer be forced to stop in certain circumstances.

4.83.0

09.03.2023

PM compatibility: 1.24.2

Option N compatibility: SW version 2.00.3 needed as a minimum because limitation of 4000 text strings has been exceeded.

Corrections:

  • Corrected issue where specific PV spinning reserve values in a plant with a battery and DGs could cause genset start/stop looping.
  • Corrected issues where PV spinning reserve values in a plant with a battery, PV, Mains and DGs would not start and stop the gensets at the correct available power.
  • The TB is closed even though a PV is the only power source connected to the busbar.
  • Corrected issue where PV did not produce the correct Q based on its capability curve and P/Q cap. limit in PMS applications.
  • Power meters in application supervision no longer shown on external BTB.
  • It is no longer possible to force CAN transmit on EIC line to stop in certain circumstances.
  • Corrected issue where PV did not produce the correct Q to meet the requested grid PF. This is when the plant operates with a voltage-based droop and the mains voltage changes.

4.82.4

03.11.2022

PM compatibility: 1.24.2

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

Corrections:

  • FMS scaling corrected.
  • CBE re-run no longer closes generator breaker directly on black busbar with cooldown control set to excitation ON.
  • MAINS unit power measured with open MB no longer added to available power in DG.

4.82.3

03.08.2022

PM compatibility: 1.24.2

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

Corrections:

  • PMS island loadsharing would not work correctly when #9030 Scaling was set to something else than default. This has been corrected. PMS asymmetrical loadsharing in island also corrected when using a different scaling than default.
  • Corrected an issue where two or more DGs could end up with the same priority.
  • In a plant where a static island is composed of mains controllers with no TB and a DG can only connect through a BTB, backsynchronization of the MBs did not work as intended. This has been improved.

4.82.2

30.06.2022

PM compatibility: 1.24.2

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

Corrections:

  • A genset will now charge a battery with the correct amount during negative PMS setpoints.
  • A genset will now calculate the correct power reference if a battery operating as an energy source is charging from excess PV power.
  • A mains could issue a start signal to DGs based on invalid power management data when a BTB was power-cycled.
  • Idle run stops engine correctly when using Low speed input.
  • In rare cases connected DGs could trip and stop, when units disconnected from PM reconnects.

4.82.1

25.03.2022

PM compatibility: 1.24.2

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

Corrections:

    • Scania EMS2 S8 is now showing the correct regeneration symbols.

4.82.0

04.03.2022

PM compatibility: 1.24.2

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

New features:

  • M-Logic flags for Enable / Disable Ext power ref via Comm and Ext frequency ref via Comm added.

Changes:

  • Busbar block handling in PMS now allowed to let the system (DG, MAINS etc.) run even though any breaker has position failure.

Corrections:

  • When setting parameter #1204 Freq trip type to 'L1 and L2 and L3', the busbar frequency alarms would end up using the generator measurement.
  • TDU can show the DEF level when Scania EMS2 S8 is used as engine I/F.
  • N + X ON/OFF via digital input or M-Logic corrected.
  • M4 multi-inputs mA scaling with AutoScale corrected.
  • Extended John Deere stage V engine protocol.

4.81.2

25.11.2021

PM compatibility: 1.24.2

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

Corrections:

1- 'Fuel optimization' and 'Fuel optimization + running hours' is now working when using percent values.
2- Translation now works even though no DU-2 is mounted AND only new language is written.
3- Deload TB before GB opens function works correctly in PEAK SHAVING.
4- CBE sequence with 'Excitation OFF during cooldown' working again. Was compromised in version 4.80.0.
5- PMS priority change via M-Logic or Modbus now works correctly.
6- CIO 308 wirebreak detection now works correctly.
7- No ASC-4 PV irradiance sensor could make AGC DG's provide inadequate power for mains power export.
8- 'PM protocol error' alarm appears if 'protocol 2' is selected, and another unit is set to protocol 1.
'Unsupported application' alarm appears if 'protocol 1' is selected and ID higher than 16 is used in the entire plant.
9- Cos-phi superior set points now work with only PV or Battery units on the busbar together with an AGC mains.

4.81.1

11.05.2021

PM compatibility: 1.24.0.

Option N compatibility: Minimum SW version 2.00.3 is needed because the limitation of 4000 text strings has been exceeded.

Corrections:

  • Channel number 4800 is no longer duplicated when M15_8 or M16_8 is mounted. All channel numbers in relation to these options are increased by ten.
  • G7 redundant plant in ISLAND mode now starts and stops properly for groups not having the start/stop signal.
  • Limit events are added in M-Logic for Extended M-Logic Alarms.
  • TDU is now able to change to BLOCK-mode. Requires TDU version 1.3.7.0.
  • Short circuit supervision (option T1) now includes PV and battery units connected. Requires ASC-4 version supporting option T1.

4.81.0

23.04.2021

PM compatibility: 1.23.0.

Option N compatibility: Minimum SW version 2.00.3 is needed because the limitation of 4000 text strings has been exceeded.

New features:

  • Four new M-Logic alarms with extended delay are added in menu 3620-3650.
  • Support of PSS module in DVC 550 is added.
  • New GOV and AVR step test is added in the parameter group #2970.

Changes:

  • Event logging is added when the application setup changes.

Corrections:

  • Generator under-frequency and under-voltage alarms are now inhibited during idle run.
  • DVC 550/D550 communication would not work correctly when EIC and ext. modules DEIF protocols were selected on two CAN ports. This is corrected.

4.80.3

05.02.2021

PM compatibility: 1.22.0.

Option N compatibility: Minimum SW version 2.00.3 is needed, because the limitation of 4000 text strings has been exceeded.

Corrections:

  • Corrected an issue that caused a mains controller to not being able to control the PF setpoint (cos phi control) on genset controllers (introduced in v.4.80.0).
  • Manual PMS priority data is maintained correctly internal in all genset controllers (introduced in 4.75.0).

4.80.2

29.01.2021

PM compatibility: 1.22.0.

Option N compatibility: Minimum SW version 2.00.3 is needed, because the limitation of 4000 text strings has been exceeded.

Corrections:

  • N + X now works when Fuel optimisation is in use.
  • QSK60G EIC auto view is now showing correct values.
  • Manual priority update now works when more than 16 gensets or mains controllers are present in the plant configuration.

4.80.1

18.12.2020

PM compatibility: 1.22.0

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

Corrections:

  • Transmit of DVC 550/D550 parameters over the CAN was irregular.
  • Menu 6231 for GB close delay no longer available when application is power management.
  • Add support for Volvo engine with 60Hz as primary speed when Volvo proprietary engine speed is used.

4-80-0

26.11.2020

PM compatibility: 1.22.0.

Option N compatibility: Minimum SW version 2.00.3 is needed, because the limitation of 4000 text strings is exceeded.

New features:

  • Configurable spinning reserve request using parameter 8930 (not supported in BTB applications).
  • The remote maintenance box (RMB) is now supported in an island Power Management configuration up to 32 DGs (requires option T4).
  • Blocking of nominal parameter set change when engine running is added. The new parameter 6016 in DG is only available from the USW.

Changes:

  • Support of ASC-4 redundancy.
  • Shows Racked out breaker On/off in the log.
  • Shows Tier-4 symbol for Scania S8 inducement failures.

Corrections:

  • Fuel optimization + running hours does not change at fixed load.
  • Corrected: Configurable amount of Fatal CAN error alarms could change when multiple units were powering up.
  • Corrected: Configuring a mains stand-alone application with the CAN bus set to OFF in the application configuration prevented the MB from closing.
  • Corrected: If a DG was running with its GB open and ground relay closed, and a mains then connected to the busbar, the ground relay would open.
  • Alarm texts from DVC550 are now shown correctly.
  • Added an alternative engine speed control for Volvo protocols including counter and checksum. Can be enabled with the new parameter 15110.
  • Added a Power derate calculation low limit for inverse proportional slope (only used for multi-inputs 102, 105 and 108 configured as mA measurement.

4-79-3

17.09.2020

PM compatibility: 1.18.0.
Includes versions: 1.02.0 & 1.17.2.

Option N compatibility: Minimum SW version 2.00.3 is needed because the limitation of 4000 text strings has been exceeded.

Corrections:

  •    New parameter #7746 DAVR AC config introduced when communicating with DVC550. This is used when split phase is needed and allows the DVC550 to follow the AC configuration on the AGC.

4.78.0

19.05.2020

PM compatibility: 1.17.2
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

New features:

  •    New selection option "Ph-Ph OR Ph-N" added in parameters #1201 and #1202 for voltage protections.

4.77.1

31.03.2020

PM compatibility: 1.17.2.
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: SW version 2.00.3 or higher is needed, because the limitation of 4000 text strings has been exceeded.

Corrections:

  •    Parameter 7801 DAVR PID Gain range is now expanded from 1-100 to 1-200.
  •    If the MB was closed at powerup, and the MB then was configured as a continuous ND signal, the MB would not operate correctly.
  •    DVC 550 M-Logic alarm events now works correctly.
  •    Resetting DVC 550 and DVC 310 alarms through M-Logic now works again.

4.77.0

11.03.2020

PM compatibility: 1.17.2.
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 is needed because limitation of 4000 text strings has been exceeded.

New features:

  •    New PT1 ramp for the Q regulation set point has been implemented.
  •    P(U) droop curve added for droop curve 1.
  •    Droop curve 1: Frequency offset can now be applied with a 4-20 mA signal for testing purposes.
  •    Configurable amount of units for triggering the Fatal CAN Error alarm added in menu 8800.
  •    Added M-Logic commands to enable and disable Easy Connect.
  •    Added individual M-Logic commands for enabling and disabling load dependent start 2 and stop 2.

Changes:

  •    Easy Connect is no longer blocking DG start in single DG applications.
       

Corrections:

  •    TB power capacity overrule timer will now run if there is an active MB trip fail class or the MB cannot be closed.

4.76.1

03.02.2020

PM compatibility: 1.17.1
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 is needed because the limitation of 4000 text strings has been exceeded.

Corrections:

  •     Ring bus applications: If BTBs were closed during the application configuration, opening a BTB could cause a DG to start without a proper start signal. This is now corrected.
  •     Corrected a situation, where opening a BTB in semi-auto mode in a plant with an active start signal would cause a DG to briefly engage its start prepare relay.
  •     In a plant with all DGs divided by open BTBs: For example, if DG1 is running and needs help from DG2, DG2 would start and close its breaker, then synchronize the BTB, and as the BTB would close, DG3 would briefly engage its start prepare relay. This has been corrected.
  •     Corrected missing translation of controller status texts for the TDU 107.

4.76.0

23.01.2020

PM compatibility: 1.17.1
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

New features:

  •    Added new M-Logic commands for changing the reference of droop curve 2.
  •    Added engine humidity derate EIC alarm on parameter  #15060. Only available for Caterpillar and Perkins engine interfaces.

Changes:

  •    LVRT set-points able to go down to 5%.
  •    Maximum timer set-point for CIO alarms increased to 999,9sec.
       

Corrections:

  •    Cosphi regulation would use limits from droop curve 2 limits even though the droop curve was disabled.

4.75.0

12.12.2019

PM compatibility: 1.17.1.
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 is needed, because limitation of 4000 text strings has been exceeded.

New features:

  •    DEIF DAVR DVC550 is now supported.
  •    NIDEC DAVR D550 is now supported (support for voltage bias regulation, for full feature support option T3 is needed).
  •    New busbar overvoltage alarm is added on parameter 1940. New busbar undervoltage alarm is added on parameter 1950.
  •    Expanded number of delta analogue alarms to 9.
  •    EIC oil and EIC coolant temperatures are now available in delta alarms for H6 modbus value. 
  •    Now possible to invert the idle relay output by disabling the 'high' setting of the Idle run parameter.
  •    Inhibits available in PMS power alarms, parameters 8220-8260.
  •    EIC Derate request is added in the selection list for Power derate.

Changes:

  •    Maximum value for all voltages in highest measure area is changed from 160 kV to 250 kV.
  •    Ground breaker change is added to the EventLog.
  •    df/dt and vector jump cannot be enbled at the same time. df/dt has priority.
       

Corrections:

  •    Genset priority would update even though the user had not issued an update.
  •    Busbar LED is now properly handled when LED color scheme 2 is active on DG displays.
  •    If mains ATS is active, the TB is closed onto a healthy busbar, and the controller is powercycled, the TB no longer opens and closes on power up.
  •    In AMF situations where the mains had no TB, #7065 mains fail ctrl was set to "Start engine", and the DGs had to connect through a BTB to supply the mains, the MB would not open, as it did not have information about whether or not the DGs Hz/V OK timer had run out. And as the MB would not open, the BTB would not close, resulting in a deadlock. This has been corrected.
  •    Service timers can now be reset.
  •    Ground breaker could unwanted flip ON-OFF-ON during transition from another controller. Corrected to keep the breaker ON during this change.

4.74.4

01.10.2019

PM compatibility: 1.17.0.
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

Corrections:

  •     Corrected: LD stop not working in AMF or Island.

4.74.3

11.09.2019

PM compatibility: 1.17.0
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 is needed because limitation of 4000 text strings has been exceeded.

Corrections:

  •    Status text interface for TDU.
  •    AGC Mains Mimic interface for TDU.

4.74.2

07.08.2019

PM compatibility: 1.17.0
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 is needed because limitation of 4000 text strings has been exceeded.

Corrections:

  •    Deload of TB is now properly handled in test mode when parameter #8273 "Deload TB back sync." is enabled.
  •    Updated Caterpillar and Perkins engine protocols for the correct handling of address claim.

4.74.1

10.07.2019

PM compatibility: 1.17.0
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.
      

Corrections:

  •     Fixed situations where multi start would not work correctly in island and amf applications.
  •     M-Logic flag "Run all available island DG's" starts all DG's when activated.
  •     Possibility of running DG's outside of easy connect plant has now been limited

4.74.0

07.06.2019

PM compatibility: 1.17.0
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 is needed because the limitation of 4000 text strings has been exceeded.

New features:

  • df/dt protection updated to meet UK G99 requirements
  • 2 New M-Logic events for Power Management status of DG breakers:
          -"Any other GB open"
          -"2 or more GB´s closed" 
  • EIC: Now it is possible to change the source address for PGN GC1 and CM1 independently of each other for all J1939 engine protocols.
    GC1 source address can be set in parameter 15040 via the Utility SW. CM1 source address can be set in parameter 15030 via the Utility SW. 

Changes:

  • Improved Easy Connect functionality:
          - Excessive alarms avoided during Easy connect sequences
          - Rapid menu changes prevented
          - Info text on removed units
          - Possibility to remove the other unit with a pop-up when only 2 in plant
          - Better handling of fault situations (Appl. hazard or Duplicate CAN ID)
          - Removed units are no longer blocked from running
          - Faster indication of changes on the other units
  • Added specific DM2 clear message for Isuzu engine protocol.
  • Added specific icon handling on the TDU Exhaust System Dashboard for Isuzu engine protocol.
          

Corrections:

  • When sending a stop command during idle start the idle relay is kept closed.
  • DEF level data for Isuzu and Scania engine protocols is now correct if selected in the Delta Analogue input list.

4.73.1

02.05.2019

PM compatibility: 1.17.0
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

Corrections:

  •    Corrected Kohler engine protocol so reset of the ECU only takes place when pulse signal for reset is received from the ECU.

4.70.0

04.04.2019

PM compatibility: 1.17.0
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

New features:

  •    Option A10 added.
  •    Fixed Q set-point added in menu 7050 for single DG.
  •    Various regulation functions added.
  •    Power ramp 3 and Power ramp 4 available via menu 2800.
  •    Generator capability curve regulator limiting added.
  •    Averaged frequency measurements added.
  •    HVRT added - available via Modbus.
  •    Power set-point control via external signals (Erzmann, RRCR etc)

Changes:

  •   Timer extended and reduced to one decimal on busbar f/U protection on level 3 and 4.
  •   df/dt ramp lowered to 1,0Hz/sec. Timer added as well.
  •   Mains sync inhibit timer extended.
  •   Capability curve setup moved to Modbus. No longer available via parameters.
  •   LVRT extended to 10 points - available on Modbus - no longer via parameters.

Corrections:

  •   Application data storage alarm working correctly.

4.71.0

04.04.2019

PM compatibility: 1.17.0
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

New features:

  •    New busbar overfrequency alarm added on parameter 1920. New busbar underfrequency alarm added on parameter 1930.
  •    Mains power measurement can now be done with CIO 308. Moved to menu 7260.
  •    Ground relay can now be configured to control a pulse breaker configuration.
  •    Ground relay can now be configured to open and close at different times.
  •    Mains reactive power measurement added to be measured via multi-input 102 or CIO308. Menu 7270 added.
  •    Mains U-L1-L2 measurement added to be measured via multi-input 102 or CIO308. Menu 7280 added.
  •    Droop curve 1 slope can now be specified in percentage relative to the nominal size of the generator.
  •    Power/frequency setpoint can now be manipulated with CIO 308 input 8. Must be configured as a 4-20 mA input.
  •    Voltage/reactive power/cosphi setpoint can now be manipulated with CIO 308 input 11. Must be configured as a 4-20 mA input.
  •    Type 1 Q(u) ext control can now be manipulated with input 23 on a CIO308 unit configured as 4-20 mA input.
  •    Type 3 Q(u) ext control can now be manipulated with input 23 on a CIO308 unit configured as 4-20 mA input.
  •    Reactive power ramp added in parameter 2820.

Corrections:

  •    Total fuel data is now correctly displayed under Engine Data in the USW.
  •    TCP/IP Modbus data in configureable was updating slowly.
  •    The unit of parameter #9250 has been changed to "lines".

4.71.1

04.04.2019

PM compatibility: 1.17.0
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

Corrections:

  •    Multiinputs 91 to 97 and 127 to 133 view texts can now be translated.
  •    When a DG with closed ground relay has its GB tripped, only the next suitable DG will close its ground relay, and not all the other DGs.

4.72.0

04.04.2019

PM compatibility: 1.17.0
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

New features:

  •    Added support for Kohler engine protocol.

Changes:

  •    Removed the 7th point on the capability curve.
  •    TSC1 transmission rate for Caterpillar/Perkins engine protocols changed to 20ms. Heartbeat message is added and transmitted for Caterpillar/Perkins engine protocols.
  •    Ground relay parameters #8124, #8131, #8133 and #8135 has had their timers extended to 30 seconds.

Corrections:

  •    Virtual events 33-96 now works again.
  •    Ground relay is no longer able to close when the controller is in "racked out breaker" mode.
  •    Parameters 7741 and 7743 are no longer overwritten with default values after a powercycle.
  •    Several mlogic event flags are now updated properly when they change state.
  •    The logic handling open and close of the ground relay when configured for pulse configuration, has been improved.

4.73.0

04.04.2019

PM compatibility: 1.17.0
Includes versions: 1.02.0 & 1.16.1.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

New features:

  •    Added two new service timers at parameter #6300 and #6310.
  •    Nominal setting for the external mains voltage measurement introduced at parameter #7284.
  •    Synchronising window can now be expanded or reduced on both sides independently.
  •    Added support for Isuzu engine protocol.

Changes:

  •    Updated MTU ECU9 Smart Connect engine protocol and added support for extra diagnostic alarms.

Corrections:

  •    Q/U ac alarms no longer fails when P is negative.
  •    Output 20 no longer activates when energy counters are set to relay and a frt happens.

4.68.2

09.01.2019

PM compatibility: 1.16.1.
Includes versions: 1.02.0 & 1.15.2.

Option N compatibility: Minimum SW version 2.00.3 is needed because the limitation of 4000 text strings has been exceeded.

Corrections:

  • Option N performance has improved.
  • Secondary ECU alarm lamps now works for Caterpillar, Perkins and Generic J1939 engine interface.

4.68.1

12.11.2018

PM compatibility: 1.16.1.
Includes versions: 1.02.0 & 1.15.2.

Option N compatibility: Minimum SW version 2.00.3 needed, because limitation of 4000 text strings has been exceeded.

Corrections:

  • Positive Busbar sequence alarm (1440) corrected behavior during power up of the controller.

 

4.68.0

26.10.2018

PM compatibility: 1.16.1
Includes versions: 1.02.0 & 1.15.2.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

New features:

  • If a busbar is black and a position fail happens, a new “busbar blocked” alarm will appear. New status texts will also inform which controller has a position failure that needs to be corrected. For more information, see the manual "Option G4, G5 and G8" 
  • When doing service on a breaker, a new feature called "Racked out breaker" is available. For more information, see the manual "Option G4, G5 and G8" 

 

4.67.0

12.06.2018

PM compatibility: 1.16.0
Includes versions: 1.02.0 & 1.15.2.

Option N compatibility: SW version 2.00.3 needed as a minimum because limitation of 4000 text strings has been exceeded.

New features:

  • P current set point and cos phi current set point can now be used for transducer output in menus 5690+5710. Values are also available on Modbus.
  • GOV and AVR regulation can now be frozen separately using M-Logic.
  • Added MB and TB open inhibit M-Logic commands.   

Changes:

  • Dynamic synchronisation minimum voltage parameter added (ch. 2024) to ensure a certain level of voltage.
  • EIC DEF Temp added in delta analogue alarms.
  • Channel number added to event log.
  • MB and TB open inhibits added in M-Logic.

Corrections:

  • A mains controller with no TB will no longer trip its MB when powercycled.
  • Relay regulation for AVR and GOV now works again.
  • In an application with multiple mains controllers without tie breakers, entering block mode on one mains could cause another mains breaker to trip shortly. Now corrected.
  • CAN Setup CH: 784x alarm no longer triggers unintentionally when selecting an EIC protocol.
  • Improved handling of config data from USW.

 

4.66.1

09.05.2018

PM compatibility: 1.16.0
Includes versions: 1.02.0 & 1.15.2.

Option N compatibility: SW version 2.00.3 needed as a minimum, because limitation of 4000 text strings has been exceeded.

New features:

  • Mains ATS functionality has been added. Can be activated when the mains is alone in an application with MB and TB. It can also be used in a power management application as backup if the power management CAN fails.
  • 16 flip flops have been added to M-Logic.
  • 64 new virtual inputs have been added.
  • ASC-4 Battery supported.
  • Double starter feature added.
  • Easy Connect feature added. Enabled in menu 8023.
  • JCB livelink support added. Enabled in menu 7552.
  • Various numbers of AC "average of all phases" alarms added. Menus 14000-14130 - only available via USW.

Changes:

  • EIC RPM overspeed (menu 7600) alarm added, also makes shutdown during shutdown override.

Corrections:

  • Beckhoff output modules updated correctly with 50 kBaud communication speed.
  • Engine fuel leakage 1 (SPN 1239) state added to M-Logic.
  • Display folios with separate mode buttons are now acting correctly when leaving BLOCK mode.
  • JCB livelink alarms on multi-inputs corrected when transmitted to DM1.

 

4.65.1

19.02.2018

PM compatibility: 1.16.0
Includes versions: 1.02.0 & 1.15.2.

Option N compatibility: SW version 2.00.3 needed as a minimum because limitation of 4000 text strings has been exceeded.

New features:

  • Support of ALC-4
  • 32DG/mains support
       • Support of 32 DGs, in ID range 1-32
       • Support of 32 mains, in ID range 1-32
       • Support of 16 ASCs, in ID range 25-40 (ASC version 4.06.0 required)
       • Support of  8 ALCs, in ID range 25-40 (ALC version 4.01.0 required)
       • New settings added for priority 17-32 in the menus 8106, 832x, 833x and 834x.
       • Fuel optimisation logic simplified. Parameters in menu 8170 removed. LD start/stop timers used instead.
       • Fuel optimisation + Running hours mode added. (To even the usage of same-size gensets).
       • Load-dependent start/stop 2 enable settings added to display menus.
       • PMS M-Logic events added for new DG/mains IDs.
       • New alarm added: "PMS protocol error". (Triggers if old software is present in a setup using DG IDs 17-32 or mains ID 1-16).
       • New alarm added: "M4 version too low". (Triggers if M4 version is below 2.03.3 in a setup using DG IDs 17-32 or mains ID 1-16).
       • Note: Quick setup and Heavy consumer features are not supporting DG IDs 17-32 and mains ID 1-16.
  • Phase sequence error can now be emulated if emulation is active.
  • Long-pressing alarm button acknowledges all alarms.

Changes:

  • EIC: Added PGN ETC3 to Caterpillar and Perkins protocols
  • EIC: Added TSC1 Checksum to Iveco protocol
  • EIC: Added CAN stop request to Deutz EMR protocol.

Corrections:

  • M-Logic version of "mains okay" command now works in the same way as the input "mains okay" command.
  • The input "mains okay" is now logged in both high and low states when it is configured either in M-Logic or through the IO list.
  • Power capacity improved to avoid overloading DGs in a setup with several TBs and a failing DG. Also, M-Logic command "TB power capacity - direct close" will now speed up AMF sequences where Mains fail control is set to "Start engine".
  • Phase sequence error status texts could appear even if they should be inhibited. GB would not close because of phase sequence error even if it was inhibited.
  • Corrected: Beckhoff digital outputs could flicker.
  • Battery test with start sequence working correctly in AUTO.
  • CIO not working together with MDEC 302/303 and ADEC 501 protocols when present on the same CAN line.
  • Restart of the controller could very rarely affect parameter settings.

 

4.60.0

20.11.2017

PM compatibility: 1.15.2
Includes versions: 1.02.0 & 1.15.1.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

New features:

  • CBE: Voltage level detection for allowing rerun added.
  • EIC Winding temp. and DEF Level added to Delta analouge input alarms
  • CBE: Setup for excitation during cooldown added.
  • LED colors can now be changed. An option to select a different LED colour behavior. Parameter 6082
  • Deload sequence can now be changed to: TB open before GB' and be enabled with parameter 8273 "Deload TB back sync."
  • Engine Communication and digital AVR is no longer required to be on the same CAN line.
  • EIC: Volvo Penta EMS 2 TIER 4 support.
  • EIC: Support of checksum in TSC1 telegram added for Volvo-Penta EMS 2.
  • EIC: Added support of CAN SENS battery charger.
  • EIC: EIC events have been mapped to Modbus.
  • EIC: DAVR available togehter with Modbus Engine Communication (means option H6 and H5 or H12 at the same time).
  • Battery test extended and can be done with a start sequence. Battery test can now crank more times. 
  • New failclass "Controlled stop" added for securing the cooldown to be executed.
  • Warm up ramp after GB synchronised added. Holds the delivered power on the "stage 1" until a wished temperature is reached on a selected input.
  • EIC: MTU J1939 Smart Connect added support for CPC4 variant.
  • EIC: PSI (Power Solutions International) J1939 protocol added.
  • EIC: PGN64913 added to PSI protocol. This PGN transmits the status of the breaker feedbacks - both GB and MB.
  • EIC: Engine derate request added on all J1939 protocols.
  • Alarm 8291 "BB meas failure" has been introduced for DG units. This alarm checks if the DG controller can measure the busbar voltage. If not, it will check if the other DGs in the PMS system can. If they can, the DG will issue an alarm.
  • Virtual AOP buttons and LED status available on Modbus.

Changes:

  • EIC: Added ambient temperature measurements to MTU ADEC protocol.
  • EIC: Volvo Penta EMS 2 support for DEF level to be read on different source addresses added.
  • In parameter #7806, the selection +-10  V has been removed. The new default selection is 0-10V.
  • Parameter #7802 is no longer available.
  • Inhibit on Ext engine stop alarm available.

Corrections:

  • When a mains is instructed to switch to a DG supply, it first checks if there is an available DG supply before opening the MB.
  • Improved update of TCP/IP Modbus data.
  • Improvements for breaker open point during power derate active.
  • Parameters 7741 and 7743 are now scaled properly in the USW according to parameter 9030. Furthermore, the minimum and maximum ranges for 7741 to 7744 have been changed.
  • Translations made in the AGC-4 does not tranfer to logs in USW or exported logs.
  • Relay error occurs when setting alarm output to limit while using Beckhoff.

 

4.59.3

15.11.2017

PM compatibility: 1.15.2
Includes versions: 1.02.0 & 1.15.1.

Option N compatibility: SW version 2.00.3 needed as a minimum, because limitation of 4000 text strings has been exceeded.

Corrections:

  • Analogue regulation parameters now visible in USW with option H12.

 

4.59.2

25.08.2017


PM compatibility: 1.15.2
Includes versions: 1.02.0 & 1.15.1.

Option N compatibility: Minimum SW version 2.00.3 is required because limitation of 4000 text strings has been exceeded.

Corrections:

  • Transducer output with AC frequency measurement as input/reference is working again.
  • MTU ADEC module 501: False EIC alarms may occur under rare conditions (option H13).
  • MTU MDEC 2000/4000 M.302 and MDEC 2000/4000 M.303: False EIC alarms may occur under rare conditions (option H5).

4.59.1

26.06.2017

PM compatibility: 1.51.2
Includes versions: 1.02.0 & 1.15.1.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

Corrections:

  • "Idle Run Stop" will now be started after "Cool Down" timer has expired.
  • Corrected possibility of translating engine communication DM1/DM2 SPN and FMI texts.
  • DG allowed to take the load with any TBs with open fail in the section, if the DG nominal power is higher than the total power capacity of TBs with open fail.
  • Option H7: Engine values were not updated correctly, if "Internal Comm" alarms are present.
  • Phase sequence errors are no longer detected when the voltage or frequency is outside "Volt/frequency ok" values.
    Correction made to make "Access Lock" block START and STOP buttons.
  • In a system with more than one mains connection, of which one of the mains is without TB, GB synch fail no longer occurs.
  • Restart during batch-write due to Beckhoff Ext I/O causing wrong parameter writings is solved. Restart no longer takes place.
  • Some common PMS set points are still working correctly after a power cycle of all units.
  • Auto start/stop OFF was not logged when using M-Logic.
  • BLOCK mode introduced in 4.59.0 in MAINS backward compatibility improved.
  • MB no longer opens unwanted, when AUS mode is active and a mains failure occurs with mode shift on.
  • Texts for Pt100 sensors on M16 updated correctly when changing language.
  • CIO 308 input alarms are now inhibited while wire break is present.

 

 

4.59.0

25.11.2016

PM compatibility: 1.15.1

Includes versions: 1.02.0 & 1.15.0.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

New features:

  •  Support of 3 x CIO-116, 3 x CIO-208 and 3 x CIO-308 modules introduced.
  •  BLOCK mode now available in MAINS. 

Changes:

  •  Disabling of heavy consumer is possible.
  •  CBE only active if an AVR relay is selected or Digital AVR type DVC 310 or D510C is selected.

Corrections:

  • DG could close onto a busbar with an MB position failure
  • A mains now behaves correctly in AMF when #7065: “Start engine” is selected and the mains is the last healthy mains in a dynamic section.
  • AVR bias was not sent if EIC control is disabled.
  • Correction to loadshare input update rate.
  • Axiomatic: Corrected unwanted External IO Comm alarm
  • Frozen reading input on external I/O module
  • External breaker alarms (ch 1981/ch 1982) added in M-Logic.
  • Correction of automatic starting and stopping gensets in power management setups.
  • Text in menu 2614 changed from “Load steps” to “Island ramp”.
  • M-Logic limit flags have now been added for the GB, MB, TB and BTB sync. failure alarms.
  • The slip-frequency comparison to sync parameters improved. Ensures that two equal frequencies can be synchronised together.
  • Evaluation of inhibits parallel/not parallel updated to prevent wrong state when using compact breaker in single DG.
  • GB handling during load test updated.
  • Evaluation of inhibits parallel/not parallel updated, so it is no longer dependent of GB/MB off states.
  • Use of specific calculated AC values optimised
  • MB handling updated in AUS mode when fail class Trip MB/GB is active.
  • The state of relay 69 and 71 when using option EF4 will now be detected correctly.
  • Mains LED handling corrected.
  • Available power alarms are now cleared when a non PMS configuration is active.
  • Ground relay function will now use the scaling and genset priorities when selecting the biggest genset.
  • Corrected oil renewal function when running hours from EIC is used.
  • Release of crank releay (remove starter) improved to be done faster after set point (rpm) is exceeded.
  • A full test is no longer terminated periodically, right after the BTB closes.

4.57.1

03.10.2016

PM compatibility: 1.15.0

Includes versions: 1.02.0 & 1.14.6.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

Changes:

  • Performance update for Option H12

Corrections:

  • Improvements made in Digital AVR mode handling

4.57.0

06.07.2016

PM compatibility: 1.15.0

Includes versions: 1.02.0 & 1.14.6.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

New features:

  • Support of upcoming products: ASC-4
  • Hysteresis for mains detection (parameter 7090) added. 

Corrections:

  • External stop is now logged in the event log.
  • Running hour counter offset could be adjusted to more than 99999 hrs.
  • During sync-to-mains in single DG with overlap, the synchronisation could fail in rare situations.
  • Correction to dynamic M-Logic evaluation shown in USW.
  • Active LTO without backsync behaves correctly regarding breaker open/close during "Exclude from Run".
  • MTU ADEC module 501: “EIC Red lamp SD.” could occur unexpectedly. (Option H13).

4.56.0

01.06.2016

PM compatibility: 1.14.6

Includes versions: 1.02.0 & 1.14.5.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

New features:

  • 'Fast crank' configuration possible.
  • Selection of 'open MB when DG ready' added for 'SingleDG' to avoid 'MB open' if start failure is present. Channel 7065.
  • Possibility to change TSC1 source address for J1939 protocols added.
  • Selection of used frequency for alarm trip added. Channel 1204.

Changes:

  • An alarm now appears if the application or M-Logic data is corrupted.
  • Status line for DEF LEVEL (EIC) corrected.
  • DAVR Warning and DAVR Trip alarms are no longer inhibited by default, when the genset is not running.
  • Various default parameters optimised - especially for diverse regulators.
  • Phase sequence error alarms can now be disabled - only via USW.
  • Phase rotation setup available via M-Logic.
  • The evaluation of MBs is optimised to avoid blackout during change of BTB.
  • Activating 'Run my ID' only once via M-Logic added.        

Corrections:

  • Digital AVR communication alarm behaviour during power-up corrected.
  • The evaluation of MBs is optimised to avoid total blackout during simultaneous mains failures.
  • Positive/negative/zero sequence now able to handle short circuit and open conductors on all phases.
  • Phase sequence error is now detected and handled at both sides of the breakers (common alarm extended to two separate alarms in menu 2150).
  • Update of energy reading and correction of display reading in regard to different scaling options.
  • State 'GEN-SET STOPPING' can no longer be terminated by changing from SEMI to AUTO.
  • Inhibit evaluation added to a number of AC alarms.
  • Two new M-Logic flags for the Beckhoff alarms "CAN1 comm error" and "CAN2 comm error" have been added.
  • CAN bus line faults could make the display very slow.
  • Missing return modes after test added.
  • TB power in emulation with open MB is now equal to the LOAD.
  • BTB close/open failure Modbus data not updated.
  • Default application for single genset no longer includes mains and MB.
  • CBE: At start failure on one DG the other DGs are now allowed to continue the CBE sequence even though the DG with failure is continuing its start attempts.
  • Parameter 1083 now shown correctly in the display.
  • Reinitialising of CAN on single CAN card could course the communication to stop.
  • EIC measure alarms are now inhibited during EIC communication failure.
  • Idle run could cause external start not to work.
  • Improvements for M-Logic cooldown/stop threshold.
  • M-Logic event 'Deactivate mode button' is now preventing any action from SEMI or AUTO key press.
  • With option T1 the redundant unit no longer causes 'Duplicate CAN ID' during switch period (power-up of master unit).
  • Nominal power for fixed power in 'SingleDG' is now following the selected nominal setting.
  • CBE breaker sequence GB+TB corrected (fault introduced in 4.55.0).

4.55.0

17.07.2015

PM compatibility: 1.14.5

Includes versions: 1.02.0 & 1.14.4.

Option N compatibility: Minimum SW version 2.00.3 needed because limitation of 4000 text strings has been exceeded.

New features:

  • Setup of CAN pms due to Baud rate and number of units in plant implemented in jump menu 9170.
  • Fast read of digital inputs on load sharing board (M12) for faster reaction time on alarms.
  • Hz/V OK timer for TB implemented in MAINS. Menu 6220 used for this purpose.
  • BTB NO/NC configurable via M-Logic. Overrules setup from plant application.
  • Direct BTB close on dead bus (A or B, A and B) implemented. Configurable via M-Logic.
  • Fast start of a section in ISLAND. Configurable via M-Logic.
  • New busbar nominal selection added to make 'BB Unom = Gen Unom'. This gives 4 pairs of nominal generator/busbar voltage like AGC-3.
  • EIC, MTU: 'Speed Demand Alarm' can be ignored. Configurable via M-Logic.
  • EIC, MTU: 'SS Override Alarm' can be ignored. Configurable via M-Logic.
  • 'Running Detection Reached' timer (parameter 6351) added.
  • 'External Engine Stop' detection (parameter 6352) added.
  • 'Frequency Detection Level' (parameter 6165) added.

Changes:

  • Caterpillar, Basler CDVR update.
  • DM secondary log buffers have been updated.
  • Exhaust port temperature has been extended from 16 to 20.
  • DM1 log has been extended from 17 faults to 32 faults.
  • "MDEC Faults" alarms text has been updated for Option H13.
  • IDLE speed RPM is always sent regardless of parameter 2781.
  • DM2 request has been changed to broadcast mode.
  • Added SPN value to event log.
  • Appl. hazard alarm extended with evaluation of number of units in plant. Information of wrong number of units stored in event log.
  • CBE: Voltage discharge timer made configurable in menu 2264 instead of being an internal timer with a fixed value of 5 seconds.

Corrections:

  • Multi input in binary mode is now represented on I/O page in USW when reading through TCP/IP.
  • Initiated cool-down cannot be aborted when a wire break fail class alarm is present.
  • Automatic update of jump menu related parameters when reading through TCP/IP.
  • Positive and negative sequence measurements for L1L3L2 corrected.
  • Start enable input was able to block GB closing sequence in Power Management, if the input was deactivated while Hz/Volt OK timer was running.
  • Improvements for GBs closing on black busbar (position feedback failure)
  • Active and reactive power measurements precision improved in L1L3L2 three-phase setup.
  • Missing deadband for peak shaving when deadband is given by a percentage.
  • LD start/stop percentage calculation is wrong if secured mode is enabled.
  • When a BTB was becoming present on the PM CAN line - e.g. after a power-up of the controller - the generators could start up accidentally (and then close again without any other problems) – problem corrected.
  • Idle run activation through digital input and reactivation after stop button function have been corrected.
  • Inverse over-current settings: "G" is displayed instead of "M" or "BA".
  • Handling of D-AVR comm. error was not correct.
  • MB was able to open even though it was excluded from the LTO sequence - corrected.
  • Scaling range 1 kV to 75 kV changed to 0.4 kV to 75 kV.
  • Too early start by DGs when Mains units are switching to test mode is now avoided.
  • Names for Menu 108x are changed for Mains and BTB units.
  • Improvements made in short circuit limitation during load test (Option T1)
  • df/dt alarm handling during change of phase setup (three/split/single) corrected to prevent missing or unwanted alarms.
  • When powering up mains units, it is now prevented that ID to run is assigned before the Power Management is up and running.
  • Start of DGs in CBE now acting correctly with one mains and no TB or two mains with TBs in an AMF situation.
  • Battery test log reading from display has been corrected.
  • ECU data not updated correct on Modbus

4.54.3

27.05.2015

Corrections:

  • In LTO, if the TB was tripped by the TB trip fail class, the MB was not able to close in all situations – corrected.

4.54.2

01.04.2015

Corrections:

  • Communication error when connected to a Digital AVR (DVC 310 and D510C)

4.54.1

19.03.2015

New features:

  • Added support for MTU ECU9
  • Performance on H5/H8 has been improved
  • Ramp speed 2 parameters added
  • Auto ramp speed selection added
  • Droop active M-Logic events added
  • Ramp speed activation M-Logic commands added

Changes:

  • Application configuration storage has been moved
  • Internal backup functionality has been updated to support moved application configuration
  • All P/Q/Cosphi droop types will now use the present value at droop start as reference point of the droop
  • Power Droop slopes are now scaled based on the droop start reference point as a percentage of the nominal power
  • Q-droop limits are now ranging from -20000 to 20000
  • Analogue input sampling has been updated in order to improve precision
  • Corrections:
  • Corrected: Wrong scaling in frequency-dependent power droop and power offsets
  • Conflict between M16 card and Q1 option
  • Redundancy not working on AGC-4 version 4.50.0
  • Corrected support of OEM products
  • Update of self-check functionality

4.50.0

09.10.2014

New features:

  • MTU ADEC CANopen interface now supports shutdown override
  • Option T2 Digital AVR support
  • ECU engine communication through the M4 engine interface (Option H7) can now be configured to operate on ‘CAN A’ or ‘CAN B’ in parameter group/menu #754x

Corrections:

  • Inverse over-current protection modified to better comply with IEC 60255 Part 151
  • No status text was shown when a GB was closed unexpectedly on a black busbar
  • Parameters 1201 + 1202 are now fixed to Phase-Neutral, when not using three-phase systems
  • Oil Renewal relay output function can now be inversed
  • Fixed Power set point was previously reduced when the genset was derated
  • Mix-up in whether phase/neutral or phase/phase measuring used for detection of Mains Failure and Mains Sync Inhibit corrected
  • Under AMF applications where a second mains fail occurs with at least one DG running, the remaining DGs are now started with a multi start No backward compatibility compromised due to this update.
  • Under AMF applications where a second mains fail occurs with at least one DG running and power cap overrule enabled, the timer is now reset (started over again) when DGs are ready and synchronised. No backward compatibility compromised due to this update.
  • Multi stop now initiates the stop sequence for all DGs at once. No backward compatibility compromised due to this update.
  • MTU MDEC 302/303 protocols battery voltage measurement corrected
  • Option N alarm transfer through e-mail did not always work
  • Navigation in parameter 9140 was incorrect
  • Incorrect alarm status on Modbus if two analogue input PCBs (Option M15) were present
  • Start enable was required to be energised, if used, to activate the breakers - corrected
  • Faulty situation where the AGC4 could reboot unexpectedly has been prevented
  • AGC Mains MB opens unwantedly - corrected. No backward compatibility compromised due to this update.
  • External I/O alarm could not be removed in some cases - corrected
  • Parameter 3410 relay A setup corrected, so display shows correct value
  • Situation avoided where MB was briefly opened in LTO mode No backward compatibility compromised due to this update.
  • After MTU has released a new software for the SMART CONNECT module, the alarm "AL Speed Demand Failure" was always present due to a change in timeout changed from ~40m[s] ==> ~10m[s]
  • 'Start engine' selection in MB fail control parameter (7065) is now used in the AMF sequences No backward compatibility compromised due to this update.
  • The reactive power was wrong when the phase rotation is L1L3L2 - corrected
  • Emulated voltage on busbar could occur, if GB was forced on and no engines were running
  • DAVR start ramp was not working under CBE after cooldown
  • AGC-4 could reboot after CAN protocol change, if there was active CAN communication on the CAN line during the protocol change
  • If an LTO sequence was initiated while an auto switch was active, an MB could end up opening and closing in endless loop - corrected No backward compatibility compromised due to this update.
  • Attempting to stop during idle at start would ramp the engine to full speed and keep it running, if the running detection speed was reached during idle run
  • Display handling slow and inconsistent if corrupt PM CAN telegrams are present
  • Unit could reboot if a Modbus command was sent while 'Inhibit modbus commands' was active

4.40.3

11.06.2014

Corrections:

  • Ranges of numbers available to select for the IP and gateway in display menus 7900 and 7910 have been updated
  • AMF sequence was incorrect in some cases
  • TB could open unwantedly when switching from AMF to LTO
  • External analogue input (option H8) parameters were reset at power up of unit
  • Genset could start when SEMI button was pushed and no start signal had been given
  • Access lock did not prevent changing mode
  • DAVR CBE sequence issues corrected
  • Idle run timer now resets at each start attempt

4.40.2

19.03.2014

Corrections:

  • External analogue input scaling and unit are now always configured at start-up and when changing the engineering unit.
  • Problem with missing element in menu 9000 corrected.
  • Access lock functionality modified. Viewing of settings is now allowed.
  • LTO sequence could not be completed on a healthy mains in case another mains was performing auto switch to it as the auto switch prevented the MB from opening. No PM backward compatibility is compromised due to this update.
  • When multiple mains are present in the application, changing plant mode from Semi to Auto during parallel operation (FP, MPE) could cause unexpected temporary power drop. No PM backward compatibility is compromised due to this update.
  • Content of Modbus addresses 1500-1504 adjusted to fit documentation.
  • Fuel pump relay could activate at power up of the controller before fuel level measurement has settled.
  • A DG already running in cool down with excitation active will, when new CBE sequence is initiated, now wait 2 s after removing excitation before reconnecting to the busbar.
  • A BTB close request was not made by the DG(s) when expected. The fault introduced in version 4.21.0. No PM backward compatibility is compromised due to this update.
  • Webarm Modbus read of enable bit incorrect
  • Possibility of Power-dependent Q alarm malfunction
  • Q reference for load sharing between groups was incorrect when asymmetrical load sharing was enabled. No backward compatibility compromised due to this update.

Changes:

  • Data update refresh rate over TCP/IP improved (option N SW version >= 2.20.0 needed).
  • Network configuration now possible via display (option N SW version >= 2.20.0 needed).
  • SW download now possible over TCP/IP (boot SW version >= 1.03.0 and USW SW version >= 3.36 needed).
  • Event log size increased to 500 events. USW 3.36 or newer needed for reading logs via TCP/IP.
  • Alarm log size increased to 500 alarms. USW 3.36 or newer needed for reading logs via TCP/IP.

New features:

  • Cylinder exhaust temperature support added for EIC Caterpillar/Perkins protocols via option H5.
  • Day tank volume added in menu 6911.
  • 2nd set of reference temperatures for analogue fan control added.
  • EIC communication error added to M-Logic.
  • BTB now able to perform black closing when being alone in application.
  • Analogue fan input list expanded to include aux. coolant temp. (SPN1212).
  • Delta analogue input list expanded to include exhaust temp. left/right.
  • Delta analogue input list expanded to include fuel diff. pressure (SPN95).
  • Support of option M16_6 (multi-input card located in slot 6).
  • Support of option M16_8 (multi-input card located in slot 8).

4.40.1

18.02.2014

PM compatibility: 1.14.1

Includes versions: 1.02.0 & 1.40.0.

Option N compatibility: As a minimum, SW version 2.00.3 is needed due to exceeding of limitation of 4000 text strings.

Corrections:

  • M15 translation texts are now updated without powercycling the unit.
  • Corrected handling and storage of M15/M16 related parameters.
  • Selection of analogue AVR regulation is back in the display menu.
  • Corrected display of RMI terminal 102, 105 and 108 parameters in the USW.
  • Prevent false readings on M16 inputs.
  • Upload of parameter min/max values and units to option N in case measure scaling is changed.
  • M16 cards sometimes drops 10% in readings momentarily.

4.30.0

31.10.2013

Corrections:

  • PM communication and EIC communication (via option H7) data could in rare occasions be mixed.
  • Setting the clock from the display does not always work.
  • Service Timer Days not adjusted when setting the date from the display menu.
  • "Mains sync. inhibit" accuracy on frequency threshold improved.
  • Option C2 inverse over current malfunction when using "Customer" defined curve corrected.
  • Strange characters could appear in alarm texts of parameter file when using translated language and USW connection was done via option N.
  • Option N speed improved in respect to various statuses such as breaker positions, running status etc. to decrease response time and improve performance on SuperVision and AGI projects.
  • Endless start attempts when using CBE and rpm thresholds set to 0rpm.
  • Vectorjump and df/dt related entries in M-logic were not available on the basis of the present of option A1.
  • Command timer now able to activate even though unit is powered up in the middle of the period.
  • Modbus "Start and close GB" are ignored while the genset is in cool down state.
  • All texts labelled "VDO" renamed to "RMI".
  • Single phase power measurements were incorrect after power cycle.
  • Start sequence was interrupted almost immediately in emulation mode when doing CBE sequences. The reason was that nominal rpm was obtained instantly.

New features:

  • Deload status being active added as an event in M-logic.
  • MTU ADEC module 501 communication (H13 option) introduced.
  • Support of new CANbus hardware "Option H5/H8.8 HW v2"
  • Logging of new mainboard "uP 8 PCB"

4.30.1

31.10.2013

Corrections:

  • Profibus communication corrected to work on mainboard "uP 8 PCB"

4.21.1

01.07.2013

Corrections:

  • False LD stop could be provoked in G7 island operation in case DG was performing load share ramp. No PM backward compatibility is compromised due to this update.
  • Mains power indication on superVision in island mode of operation always displayed zero. No PM backward compatibility is compromised due to this update.
  • Synchronising last open BTB located furthest to the right in a ringbus application could fail. In case mains connected to busbar on its left side and DG(s) on its right side, the DG(s) would not receive the command of performing synchronisation. No PM backward compatibility is compromised due to this update.
  • Last 2 open BTBs in a ringbus application could both initiate synchronisation at the same time in SEMI auto and consequently close at the same time, even though closed ring was not allowed. No PM backward compatibility is compromised due to this update.
  • Capacity overrule did not work in case "Start engine" was selected and mains configured with MB and TB. No PM backward compatibility is compromised due to this update.
  • Incorrect M-Logic interpretation corrected.
  • CBE sequence updated so the excitation relay is kept energised throughout the cool down sequence in case voltage is present on the busbar.
  • GB(s) could trip unexpectedly in applications with mains without TB. Phenomenon could occur in case MB was performing back synchronisation and experienced an MB close failure. No PM backward compatibility is compromised due to this update.
  • Part of positive sequence alarm did always look at BB voltages though the device type demanded it to act on gen. voltages.
  • If doing LTO without sync. to mains or AMF with "Start engine", MB would trip when DG volt./freq. okay, although the DG was performing initial idle sequence. Now MB waits until DG is ready.
  • Correction to idle sequence when idle stop not used.
  • DG not being under PMS control was still contributing to power summations used as basis for power reference calculations. PM backward compatibility is compromised due to this update in respect of taking DGs out of PMS control.
  • When synchronising BTB to external/unknown voltage source, the DGs online would not always react according to synchronisation command sent from the BTB. No PM backward compatibility is compromised due to this update.
  • M-Logic command "Start and Close GB" was ignored during cool down.
  • Idle run could elapse more than once during start sequence.
  • Wrong calculation in Cummins PCC load share interface.
  • H7 communication transmission jitter reduced to avoid abnormal update rate
  • H7 SCANIA EMS2 correction of start/stop

Changes:

  • Mains voltage removed in emulation in case island mode selected and application is without presence of MB.
  • Menu 9030 for voltage range of operation was not reachable via USW (USW3.34 or newer needed).
  • Menu 10390-10410 for password access level to log, language and control page removed. They are no longer active as they have been substituted for permissions.
  • "Ghost image" functionality moved from menu 9080 to menu 9230 and renamed to "Memory backup".
  • Various checks for BTB initialising close sequence bypassed in case BTB configured as normally open and in auto mode.No PM backward compatibility is compromised due to this update.
  • Ground relay. Changed the way the ground relay is activated. Prioritising is now the most significant PM-priority number instead of the most significant CAN ID.
    PM backward compatibility is compromised due to this update in respect of ground relay functionality.

New features:

  • Idle run supported in emulation.
  • Functionality for limiting amount of nominal power allowed on busbar at a time due to limitations of short circuit current expanded to be included in the system logics of the DG and mains. Until now it has only been supported by BTB units to determine wheter connecting to sections was allowed. No PM backward compatibility is compromised due to this update.
  • Possibility of closing all BTBs in a ringbus application added. No PM backward compatibility is compromised due to this update.
  • TB synchronisation will now be initiated in case the multi-start forces start of too few DG(s) to get sufficient available power on busbar to meet the power reference. No PM backward compatibility is compromised due to this update.
  • TB deload request added in M-Logic. No PM backward compatibility is compromised due to this update.
  • Activate droop regulation added in M-Logic.
  • Readout of active fail classes on Modbus address 1057.

4.20.2

23.11.2012

PM compatibility: 1.12.1

Includes versions: 1.01.4 & 1.12.0.

N-option compatibility: As a minimum, SW version 2.00.3 is needed due to exceeding of limitation of 4000 text strings.

Corrections:

  • It was not possible to clear fast alarms such as vector jump on a mains unit in case no mains voltage was present.
  • The resolution of fixed power reference sent from the Mains unit to the DG(s) was ependent on the power measurement resolution of the Mains unit itself. In case Mains unit used caling range [10-160 kV] for instance, the fixed power reference sent to DG(s) were in 1/10 of MW accuracy.
  • No PM backward compatibility is compromised due to this update.

Changes:

  • Minimum timer setting for capacity overrule decreased from 5.0 s to 0.0 s.

4.20.1

02.11.2012

PM compatibility: 1.12.0

Includes versions: 1.01.4 & 1.11.2.

Webarm/N-option compatibility: Mininum SW version 2.00.3 needed due to limitation of 4000 text strings exceeded.

Corrections:

  • Scaling of analogue inputs on Beckhoff modules corrected.
  • Unexpected trip of GB in SingleDG application when using overlap functionality

4.20.0

12.10.2012

PM compatibility: 1.12.0

Includes versions: 1.01.4 & 1.11.2.

N-option compatibility: SW version 2.00.3 needed as a minimum.

New features

  • Parameter modified support added. 
  • Controller redundancy support added.
  • Breaker, engine & mains transformer names made part of identifiers.
  • Ghost image support for backup/restoring of unit in respect to parameters, options, application, etc.
  • Additional engine values supported in MDEC protocol.
  • RPM from engine communication can now be used in CBE sequence.
  • Emulation update for support of single and split phase systems.

Corrections:

  • Scaled texts are now also updated to the correct language when changing the language parameter and when the unit is started up.
  • Shifting between power management applications containing BTB(s) on the fly could fail. No PM Backward compatibility is compromised due to this update. 
  • Data update to N-option stock on updating parameter values due to constant writing to parameter for voltage-depending overcurrent during operation.
  • Follow up - display could still freeze up. Could happen after writing of M-logic configuration.
  • Axiomatic texts always presented in master language.
  • Busbar LED on plant management fascia now also illuminated in single DG applications where no MB is present.
  • The H6 option data is not updated on N option.
  • M-logic commands could prevent proper data update to N-option.
  • Password level set via USW for jump menus did not work.
  • Q reference used in power management in island operation when doing asymmetrical load share was incorrect. No PM Backward compatibility is compromised due to this update.
  • Slope resolution for PF droop increased with a factor of 10.
  • GOV/AVR-related parameters were missing in USW even though EF6 option present.
  • RMB: Generator can stop when selecting RMB mode or connecting RMB box.
  • RMB: Power setpoint not reset before Deload Mains mode.
  • RMB: Input/Relay error.
  • Analogue fan contributions set to minimum in case associated scaling set to zero.
  • Translation of two CAN alarm texts did not take effect before a power cycle was performed.
  • Shutdown override does not prevent transmission of stop command to ECU when fail class shutdown provoked.

4.10.2

12.07.2012

PM compatibility: 1.11.2

Includes versions: 1.01.3 & 1.11.1.

Corrections:

  • High frequency (above 150Hz) immunity on AC voltage input implemented.
  • Volvo engine no longer start up after end of battery test.
  • Rare freeze of the display after power up.

4.10.1

11.07.2012

PM compatibility: 1.11.2

Includes versions: 1.01.3 & 1.11.1.

Corrections:

  • Reading and writing using PROFIBUS is now limited to the correct range.
  • Shift of phase system from within m-logic did not work properly

4.10.0

10.07.2012

PM compatibility: 1.11.2

Includes versions: 1.01.3 & 1.11.1.

New features

  • 1- "Clear Log" modbus command added. 
  • Support of Ground breaker feedback handling. No PM Backward compatibility is compromised due to this update.
  • Mains sync. inhibit functionality added.
  • Five dedicated Mlogic alarms added.
  • View line informing about active regulators added.
  • View line containing power and Gen-L1N added.
  • Inhibit edit of fuel fill check alarm added.
  • Additional input selections made available in "Power Derate", "Engine heater", "Cool down threshold" & "Fan control".
  • Average U bushar high alarms added (menu 7480 + 7490).
  • M-logic flag for acknowledge all AC mains protection alarms added.

Changes:

  • Power dependent Q import/export alarm modified to have separate parameter for VA
    reference.
  • U and Q low (1960 + 1970) alarms demands extended with two parameters (minimum current and phase angle) before the alarm can be activated on behalf of the voltage goes below the set point.

Corrections:

  • Endless closing/opening of MB in a Multi-Mains application in case
  • Overlap functionality enabled and a MB on a Mains is opened in LTO sequence which is not supposed to run.
  • No PM Backward compatibility is compromised due to this update.
  • Hold Ground Relay active once V/Hz in range detected (avoids potential flickering)
  • When bigger DG connects to busbar it deactivate/activated the ground relay once.
  • When BTB deloading secure ground connection on both side of BTB.
  • No PM Backward compatibility is compromised due to these updates.
  • Swap timer in Fuel Optimization priority routine was not cleared properly.
  • EIC: MTU Smart Connect 'EIC faults' handled correct.
  • Power produced by Plant Management System could deviate from reference.
  • No PM Backward compatibility is compromised due to this update.

4.04.0

04.03.2012

PM compatibility: 1.11.1

Includes versions: 1.00.0, 1.00.1, 1.00.2, 1.00.3, 1.10.0, 1.10.1, 1.10.2 & 1.11.0.

New features:

  • GOV and AVR signals can be inversed via analogue outputs. Use 'Inverse proportional' flag in menu 2781 (GOV) and 2782 (AVR).
  • Status text "preparing engine if." added.

Changes:

  • Ground Relay functionality modified. Close command to the ground breaker has been postponed from being send at start up to being send when generator voltage and frequency
    is within operating range.
  • No Backward compatibility is compromised due to this update.

Corrections:

  • U and Q low (1960 + 1970) alarms reaction time enhanced (faster reaction) when alarm state is caused by phase value and voltage already below set point.
  • Relay regulation now working correct with small differences (0,1Hz and 0,2Hz) between dfMax (ch 2021) and dfMin (ch 2022) for dynamic sync.
  • SMS functionality corrected.
  • EIC: Receiving single DM1 diagnostic not restricted in content any longer for all J1939 protocols.
  • External communication alarm was falsely provoked when using profibus communication.
  • Scaling of 4-20mA on analogue input in slot#8 conflicted with scaling of analogue inputs  in slot#6.

4.03.0

09.02.2012

PM compatibility: 1.11.0

Includes versions: 1.00.0, 1.00.1, 1.00.2, 1.00.3, 1.10.0, 1.10.1 & 1.10.2.

New features:

  • "Woodward SPM-D11" added as possible type of load-share units to interface to.
  • "Oil filter differential pressure" added as selection in Delta Analogue alarms.

Corrections:

  • If "DG missing" alarm was present as well as G3 option the unit would switch to analogue var-sharing. Now the automatic switching is removed and the user have to use the M-logic event Analogue Loadsharing and this give both var-sharing and kW-sharing.
  • Voltage level for analogue load-share where reset to 4.0V at every power up when "CumminsPCC" was selected.

4.02.0

01.02.2012

New features:

Additional Delta Analogue alarms 4-6 added.

Changes:

  • Ground Relay handling updated. Ground Relay activates as DG start up and remains activated until GB closed. Ground relay will open again in case GB closed and larger DG being on busbar and not preparing to disconnect has Ground Relay active. PM compatibility compromised in respect to GroundRelay functionality. Code prepared for breaker feedback handling though so support of this should be possible to implement without further compromising of compatibility.
  • DG able to abort on-going stop sequence as long as extended stop sequence not yet initiated.
  • 3 PGN's where only accepted by AGC if send with priority 6 now also accepted if send with priority 3.
  • OEM display leds for yellow/red alarm where looking at red/yellow info from ECU directly. The display led handling is now hung up on the AGC EIC Warning/Shutdown alarms instead.
  • Service timer 2 initialized to 0 at download.

Corrections:

  • Lamp test did not match an OEM display folio.
  • EIC Autoview did not detect 3 resently added J1939 values.
  • Menu1130 & 1140 displayed ##.##s instead of ###.#s in editing window.
  • Update of Text strings to N-option improved.
  • Minimum setting for analogue regulation output was initialized to zero at every power up when using option EF5 or EF6.

4.01.1

16.01.2012

  • I/O texts for breaker relays and feedbacks are now updated to N-option when breaker configuration is changed.
  • Translation texts are now being read correctly when connected via TCP/IP.
  • Texts used for presentation of 3 phase measurements are now updated "on the fly" when phase system is changed via M-logic. Device had to be powered down/up before refreshing the relevant texts. This is no longer necessary.
  • EIC: Caterpillar (Perkins) support of two DM1 logs is now placing diagnostic codes in the correct log when using option H7.

4.01.0

16.12.2011

PM compatibility version 1.10.2.

Includes versions: 1.00.0, 1.00.1, 1.00.2, 1.00.3, 1.10.0 & 1.10.1.

New features:

  • Support of new OEM costumer.
  • Crank and start failure added to list of alarms in Mlogic.
  • 60Hz system (event true when nominal frequency above 55.0Hz) added to list of events in Mlogic.

Changes:

  • EIC: DM1 log entries now saved in standard Event Log.
  • SPN for the alarms can be read via USW Event Log.
  • EIC: Occurrence counter available in DM1 and DM2 logs.

Corrections:

  • Unwanted retrieval of command status by a unit powering up in a power management application.
  • No backward compatibility compromised due to this update.

4.00.1

12.12.2011

PM compatibility version 1.01.1.

Includes versions: 1.00.0, 1.00.1, 1.00.2 & 1.10.0.

New features:

  • In emulation mode the Fuel Pump Logic functionality is now coupled to the emulated fuel level which enables it to fill up the fuel tank.
  • Possible selections for Fuel Pump Logic Input type expanded to include M15_X options as well as external analogue inputs.

Corrections:

  • Initialization of internal communication could some times fail at power up resulting in "internal comm." alarm.
  • Initialization of N-option could some times result in garbage/missing parameter data after firmware update.
  • A normally closed Vac BTB being in AUTO and ready to close, but unable to do so due to missing BA and BB voltage, could block for other BTB in the system to perform automatic closing. No Backward compatibility is compromised due to this update.
  • Incorrect voltage reference would be used by DG(s) when synchronizing a BTB against Mains connection(s). Phenomenon occurred when BTB was synchronizing with DG(s) connected to busbar on one side and only Main(s) connected to the other.  No Backward compatibility is compromised due to this update.
  • Heavy consumer was corrupted due to optimization made in version 4.00.0. Error now corrected. Backward compatibility towards older PM versions remains compromised.
  • Overlap functionality did not work in emulation mode

4.00.0

06.12.2011

PM compatibility version 1.10.0
Includes versions 1.00.0 and 1.00.1

Features:
1- Option G7 “Plant Management” introduced. Two new product types introduced in this context:
a. Gen-set group tie unit.
b. Plant unit.
2- Option "Emulation" introduced.
3- Option H9 "modbus RS232" introduced.
4- 4 different voltage/power scalings introduced covering range from 10V/1.0kW up to 160kV/900.0MW.
It is possible to have controllers using different scaling within a power management application.
Contollers having PM compatibility version 1.00.0 or newer are able to understand if other
controllers are using scaling even though they are inable of performing scaling themselfes.
5- Separate settings for nominal busbar voltage introduced enabling synchronization over step
up/down transformers.
6- Menu7054 in Mains unit for enabling common cosphi reference to DG(s) expanded.
Possibility of making cosphi reference for DG(s) load dependent to hold fixed cosphi across MB
added:
a. Off (DG, Mains, Gen-set group tie and Plant units).
b. Fixed for DG(s) (Mains, Gen-set group tie and Plant units).
c. Fixed for imp/exp (Mains, Gen-set group tie and Plant units).
d. Superior (DG and Gen-set group tie units).
No PM backward compatibility is compromised.
In fact DG(s) with older PM compatibility versions will be able to handle if “Fixed for imp/exp”
is selected in the Mains unit. “Superior” is the setting used for taking in cosphi reference
from unit placed at higher level in the system. If for instance DG(s) are to take in reference
from a Mains unit, “Superior” must be selected in the DG(s).
If DG(s) are to use their local reference the setting must be set to “Off”.
In case “Fixed for imp/exp” is selected in a Mains unit it will seek to compensate for any DG(s)
not being in “Superior” to maintain the requested cosphi across its MB. DG(s) with older PM
compatibility version will behave as if “Superior” was selected and will therefore only use
local reference in case no reference is received from the mains unit.

  • Load profiled running hour counter added. This counter is weighted with the percentage load of the DG.  This counter is selectable as type of running hour on which to base DG priority in menu8113:  a. Total. b. Trip. c. Load profiled. Load profiled selection will not be compatible with units having older PM compatibility versions.
  • Priority handling updated. Now it is possible to make manually update of priorities in Menu8086 depending on either user defined priority order or according to running hours. a. Off. b. Manually update. c. Running hour update. This is independent on priority routine selected of the type selected in menu8113. No PM Backward compatibility is compromised due to this update.
  • Possibility of subtracting DG(s) from Power Management system added. It is now possible to select a Gen-set mode in menu6071 other than “Power management”  when being part of a Power Management application. When doing so normal operation of a SingleDG will be obtained.  The DG(s) will no longer be available to the Power Management system.  The Power Management communication itself will remain intact and no alarms will be introduced in the system.  No PM backward compatibility is compromised due to this update.

Auf dieser Seite können Sie Software-Updates für Ihr(e) Produkt(e) herunterladen und sich verschiedene Utility-Tools und Add-ons beschaffen, die Ihnen beim Einrichten und Konfigurieren Ihres Produkts/Ihrer Produkte sowie bei der entsprechenden Fehlersuche behilflich sein können.

Beachten Sie bitte, dass nicht alle unsere Produkte vom Benutzer aktualisiert werden können. Es werden auch nicht alle unsere Produkte mit einem Utility-Tool geliefert. Somit kann die Liste auf dieser Seite nicht als Übersicht unseres kompletten Produktsortiments angesehen werden.

DEIF registriert Ihren Download zusammen mit der verwendeten E-Mail-Adresse, um Ihnen auf Anfrage Informationen zu künftigen Updates zuzusenden.

DEIF kann nicht für die Folgen fehlgeschlagener Produkt-Updates oder die Nutzung von Utility-Tools haftbar gemacht werden. Auch haftet DEIF A/S nicht für die Folgen einer Verhaltensänderung von Produkten aufgrund eines Software-Upgrades. Es obliegt stets dem Anwender, vor der Inbetriebnahme die korrekte Einrichtung und Konfiguration sicherzustellen. Sehen Sie sich vor der Aktualisierung des Produkts das Versionsprotokoll der Software an.

Lizenzvereinbarung für den Software-Download von www.deif.com

Heruntergeladene Software bleibt Eigentum von DEIF. Die Software wurde möglicherweise nicht für gewerbliche Zwecke ausgegeben, sie wurde vollständig oder partiell geändert oder wiederverwendet oder sie wurde an jedwede Drittanbieter verkauft.Auf dieser Seite können Sie Software-Updates für Ihr(e) Produkt(e) herunterladen und sich verschiedene Utility-Tools und Add-ons beschaffen, die Ihnen beim Einrichten und Konfigurieren Ihres Produkts/Ihrer Produkte sowie bei der entsprechenden Fehlersuche behilflich sein können. 

Die aktuellste Version für volle Funktionalität

Wir empfehlen Ihnen, die von uns bereitgestellten Updates zu installieren, um so das volle Potenzial Ihres DEIF-Produkts nutzen zu können.

Die gesamte optimierte Software kann nach Belieben unter www.deif.com heruntergeladen werden. Navigieren Sie dazu zu „Software“ und dann zu „Software-Download“.

Bei Fragen oder Problemen beim Auffinden der entsprechenden Software für Ihr Produkt wenden Sie sich telefonisch unter der Rufnummer +45 96149614 an DEIF A/S oder an die jeweilige lokale DEIF-Niederlassung. Alternativ können Sie uns auch eine E-Mail an support@deif.com senden. Wir helfen Ihnen gerne weiter.

Press release, June 2015

Information on product improvement specifically related to “older” DEIF A/S ML-2 products.